Engineered fromthe electron up.
Logicode designs the electronics, wireless systems, energy systems and software that keep buildings, plant and organisations operating, and integrates them as a single system.
Systems rarely fail on the test bench. They fail at the end of a long cable run, behind a concrete wall, or during a power interruption. Logicode designs for those conditions.
Four engineering disciplines, delivered under one contract.
01 / 04
Printed circuit assemblies and embedded firmware, designed for volume manufacture and field service.
Explore Electronics02 / 04
Wireless connectivity engineered for the site: range, interference and service life.
Explore Wireless & IoT04 / 04
Applications, data platforms and AI, deployed where the organisation requires.
Explore Software & AIFour engineering disciplines, delivered under one contract.
01 / 04
ElectronicsPrinted circuit assemblies and embedded firmware, designed for volume manufacture and field service.
02 / 04
Wireless & IoTWireless connectivity engineered for the site: range, interference and service life.
03 / 04
EnergyGeneration, storage and energy management, sized from measured data.
04 / 04
Software & AIApplications, data platforms and AI, deployed where the organisation requires.
Integrated delivery
One accountable team.
Single design authority
One team is responsible for the board, the radio link, the power system and the software, so each interface is specified once and agreed once.
In brief The same people design every part, so the parts fit the first time.
Technical detail
One set of drawings, one issue tracker and one interface specification across all four disciplines.
Single point of support
Faults are diagnosed by engineers who know the complete system, across power quality, radio performance, firmware and application data.
In brief When something goes wrong, the people who answer know the whole system.
Technical detail
Fault-finding starts from the full picture: power quality, radio link, firmware logs and application data together.
Single record, owned by the client
All design and as-built information is maintained together and transferred to the client at handover.
In brief Everything is documented in one place and handed to you at the end.
Technical detail
Schematics, Gerber files, firmware and application source, BIM models and as-built drawings, in the client's repository.
Operating principles
Operating principles · 01 / 05
Measurement precedes design.
Designs are based on logged data: electrical demand, radio signal levels and machine run times.
Operating principles · 02 / 05
Designed for adverse conditions.
During a power interruption, interference or loss of connectivity, a system must raise an alarm, continue operating and recover without a site visit.
Operating principles · 03 / 05
One system, one record.
Hardware, radio, power and software are documented together, in drawings and a building model that are kept current.
Operating principles · 04 / 05
Verified where it operates.
Equipment is tested at its installed location, in its final enclosure, before a design is released.
Operating principles · 05 / 05
Complete handover.
Schematics, firmware, source code, models and drawings are transferred to the client, who may operate, extend or re-tender the system.
Industries
Sectors served.
Buildings & Property
Metered, controlled and documented buildings.
Energy & Utilities
Generation and storage for sites that cannot depend on the grid.
Manufacturing
Production data from every machine, including legacy equipment.
Agriculture
Field, water and cold-chain data, reported remotely.
Data Centres & Telecom
Monitoring and backup for power and cooling.
Research
Recent technical papers.
- 01Running open-weight AI models on your own hardwareA method for estimating whether an open-weight language model fits in a machine's memory and how fast it will generate, from parameter count, quantisation and memory bandwidth.9 min read→
- 02Wi-Fi, Bluetooth, LoRaWAN or cellular: choosing a radio for an IoT deviceA selection method for the radio in a connected device, based on the data requirement, a link budget and the average current drawn from the battery.9 min read→
- 03Reading signal strength: dBm, RSSI and SNRThe meaning of the three figures reported by wireless equipment, how they relate through path loss and noise, and the levels at which a link can be relied upon.8 min read→
Engagement
Terms of engagement.
- Working day to respond to a new enquiry
- 1
- Engineering disciplines under one contract
- 4
- Of drawings, source code and firmware transferred to the client
- 100%
